The Radon Dosimetry Team operates a radon exposure facility for calibration, testing, and research purposes. Radon gas concentrations are measured using instruments that are calibrated to traceable standards using a source from an accredited laboratory.  

Our expertise covers both passive and active (electronic) radon detectors, and our radon scientists have many years’ experience in applying that knowledge to more unusual measurement situations. We provide calibration of passive detectors, active radon monitors and radon integrated electronic devices.

Radon detectors must be calibrated in order to respond correctly. Passive detectors are calibrated before being issued. Electronic radon detectors must be calibrated before first use and annually thereafter if they are being used for compliance with the Ionising Radiations Regulations 2017. 

Whether it is passive detectors, active instruments or one of the many Electronic Radon Integrated Monitors (ERIMs) introduced in recent years, these must all be calibrated to ensure that the radon monitor is giving an accurate and reliable reading. 

Manufacturers of passive radon detectors can submit sample etched track detectors for known exposures to ensure that the detector elements are of the correct sensitivity and that their track reading system is functioning correctly. 

For instruments being used to measure radon levels in workplaces, the Ionising Radiations Regulations 2017 apply. These regulations state that instruments must be calibrated before use and then annually. 

We strongly recommend annual calibrations for any instrument being used to monitor radon. 

This is a selective list of some of the calibration services we currently provide – if you don’t see your instrument, detector or device, contact [email protected].

  • one week calibration of up to 2000 etched track monitors, F monitored 
  • longer exposures are available on a daily rate, F monitored 
  • This is an extract. The publication continues at the source.

    Contains public sector information licensed under the Open Government Licence v3.0. Licence

    Read the original at the source: https://www.gov.uk/guidance/radon-technical-and-laboratory-services-for-professionals

    Officially imported this from UK Health Security Agency’s own source and shows an extract. If you work there, claiming the profile and verifying the domain lets you choose to show the full text here.

    Provenance

    Organization
    UK Health Security Agency — imported from official source
    Official source
    https://www.gov.uk/government/organisations/uk-health-security-agency.atom ATOM
    Imported
    November 18, 2026 10:02
    Versions
    1 recorded
    Identity
    https://www.gov.uk/guidance/radon-technical-and-laboratory-services-for-professionals#2...

    Officially records where a publication came from, not whether it is true. Imported records are reproduced from an organization's own official source.